欧美一区二区三区老妇人-欧美做爰猛烈大尺度电-99久久夜色精品国产亚洲a-亚洲福利视频一区二区

vb.netinet的簡單介紹

怎樣在VB.net中獲得ping命令的結果

首先添加一模塊,代碼如下

十余年專注成都網(wǎng)站制作,企業(yè)網(wǎng)站建設,個人網(wǎng)站制作服務,為大家分享網(wǎng)站制作知識、方案,網(wǎng)站設計流程、步驟,成功服務上千家企業(yè)。為您提供網(wǎng)站建設,網(wǎng)站制作,網(wǎng)頁設計及定制高端網(wǎng)站建設服務,專注于企業(yè)網(wǎng)站建設,高端網(wǎng)頁制作,對發(fā)電機回收等多個領域,擁有豐富的網(wǎng)站運維經(jīng)驗。

Option Explicit

Private Const IP_SUCCESS As Long = 0

Private Const IP_STATUS_BASE As Long = 11000

Private Const IP_BUF_TOO_SMALL As Long = (11000 + 1)

Private Const IP_DEST_NET_UNREACHABLE As Long = (11000 + 2)

Private Const IP_DEST_HOST_UNREACHABLE As Long = (11000 + 3)

Private Const IP_DEST_PROT_UNREACHABLE As Long = (11000 + 4)

Private Const IP_DEST_PORT_UNREACHABLE As Long = (11000 + 5)

Private Const IP_NO_RESOURCES As Long = (11000 + 6)

Private Const IP_BAD_OPTION As Long = (11000 + 7)

Private Const IP_HW_ERROR As Long = (11000 + 8)

Private Const IP_PACKET_TOO_BIG As Long = (11000 + 9)

Private Const IP_REQ_TIMED_OUT As Long = (11000 + 10)

Private Const IP_BAD_REQ As Long = (11000 + 11)

Private Const IP_BAD_ROUTE As Long = (11000 + 12)

Private Const IP_TTL_EXPIRED_TRANSIT As Long = (11000 + 13)

Private Const IP_TTL_EXPIRED_REASSEM As Long = (11000 + 14)

Private Const IP_PARAM_PROBLEM As Long = (11000 + 15)

Private Const IP_SOURCE_QUENCH As Long = (11000 + 16)

Private Const IP_OPTION_TOO_BIG As Long = (11000 + 17)

Private Const IP_BAD_DESTINATION As Long = (11000 + 18)

Private Const IP_ADDR_DELETED As Long = (11000 + 19)

Private Const IP_SPEC_MTU_CHANGE As Long = (11000 + 20)

Private Const IP_MTU_CHANGE As Long = (11000 + 21)

Private Const IP_UNLOAD As Long = (11000 + 22)

Private Const IP_ADDR_ADDED As Long = (11000 + 23)

Private Const IP_GENERAL_FAILURE As Long = (11000 + 50)

Private Const MAX_IP_STATUS As Long = (11000 + 50)

Private Const IP_PENDING As Long = (11000 + 255)

Private Const PING_TIMEOUT As Long = 500

Private Const WS_VERSION_REQD As Long = H101

Private Const MIN_SOCKETS_REQD As Long = 1

Private Const SOCKET_ERROR As Long = -1

Private Const INADDR_NONE As Long = HFFFFFFFF

Private Const MAX_WSADescription As Long = 256

Private Const MAX_WSASYSStatus As Long = 128

Public PingTime As Long

Private Type ICMP_OPTIONS

Ttl As Byte

Tos As Byte

Flags As Byte

OptionsSize As Byte

OptionsData As Long

End Type

Private Type ICMP_ECHO_REPLY

Address As Long

status As Long

RoundTripTime As Long

DataSize As Long

DataPointer As Long

Options As ICMP_OPTIONS

Data As String * 250

End Type

Private Type WSADATA

wVersion As Integer

wHighVersion As Integer

szDescription(0 To MAX_WSADescription) As Byte

szSystemStatus(0 To MAX_WSASYSStatus) As Byte

wMaxSockets As Long

wMaxUDPDG As Long

dwVendorInfo As Long

End Type

Public Declare Function timeGetTime Lib "winmm.dll" () As Long

Private Declare Function WSAStartup Lib "wsock32" (ByVal wVersionRequired As Long, lpWSADATA As WSADATA) As Long

Private Declare Function WSACleanup Lib "wsock32" () As Long

Private Declare Function IcmpCreateFile Lib "icmp.dll" () As Long

Private Declare Function inet_addr Lib "wsock32" (ByVal s As String) As Long

Private Declare Function IcmpCloseHandle Lib "icmp.dll" (ByVal IcmpHandle As Long) As Long

Private Declare Function IcmpSendEcho Lib "icmp.dll" (ByVal IcmpHandle As Long, ByVal DestinationAddress As Long, ByVal RequestData As String, ByVal RequestSize As Long, ByVal RequestOptions As Long, ReplyBuffer As ICMP_ECHO_REPLY, ByVal ReplySize As Long, ByVal Timeout As Long) As Long

'Private Declare Function WSAGetLastError Lib "wsock32" () As Long

'Private Declare Function gethostname Lib "wsock32" (ByVal szHost As String, ByVal dwHostLen As Long) As Long

'Private Declare Function gethostbyname Lib "wsock32" (ByVal szHost As String) As Long

'Private Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" (xDest As Any, xSource As Any, ByVal nbytes As Long)

Private Function GetStatusCode(status As Long) As String

On Error GoTo ErrLine

Dim Msg As String

GetStatusCode = ""

Select Case status

Case IP_SUCCESS: Msg = "ip success"

Case INADDR_NONE: Msg = "inet_addr: bad IP format"

Case IP_BUF_TOO_SMALL: Msg = "ip buf too_small"

Case IP_DEST_NET_UNREACHABLE: Msg = "ip dest net unreachable"

Case IP_DEST_HOST_UNREACHABLE: Msg = "ip dest host unreachable"

Case IP_DEST_PROT_UNREACHABLE: Msg = "ip dest port unreachable"

Case IP_DEST_PORT_UNREACHABLE: Msg = "ip dest port unreachable"

Case IP_NO_RESOURCES: Msg = "ip no resources"

Case IP_BAD_OPTION: Msg = "ip bad option"

Case IP_HW_ERROR: Msg = "ip hw_error"

Case IP_PACKET_TOO_BIG: Msg = "ip packet too_big"

Case IP_REQ_TIMED_OUT: Msg = "ip req timed out"

Case IP_BAD_REQ: Msg = "ip bad req"

Case IP_BAD_ROUTE: Msg = "ip bad route"

Case IP_TTL_EXPIRED_TRANSIT: Msg = "ip ttl expired transit"

Case IP_TTL_EXPIRED_REASSEM: Msg = "ip ttl expired reassem"

Case IP_PARAM_PROBLEM: Msg = "ip param_problem"

Case IP_SOURCE_QUENCH: Msg = "ip source quench"

Case IP_OPTION_TOO_BIG: Msg = "ip option too_big"

Case IP_BAD_DESTINATION: Msg = "ip bad destination"

Case IP_ADDR_DELETED: Msg = "ip addr deleted"

Case IP_SPEC_MTU_CHANGE: Msg = "ip spec mtu change"

Case IP_MTU_CHANGE: Msg = "ip mtu_change"

Case IP_UNLOAD: Msg = "ip unload"

Case IP_ADDR_ADDED: Msg = "ip addr added"

Case IP_GENERAL_FAILURE: Msg = "ip general failure"

Case IP_PENDING: Msg = "ip pending"

Case PING_TIMEOUT: Msg = "ping timeout"

Case Else: Msg = "unknown msg returned"

End Select

GetStatusCode = Msg

Exit Function

ErrLine:

End Function

Private Function Ping(sAddress As String, sDataToSend As String, ECHO As ICMP_ECHO_REPLY) As Long

On Error GoTo ErrLine

Dim hPort As Long

Dim dwAddress As Long

dwAddress = inet_addr(sAddress)

If dwAddress INADDR_NONE Then

hPort = IcmpCreateFile()

If hPort Then

Call IcmpSendEcho(hPort, dwAddress, sDataToSend, Len(sDataToSend), 0, ECHO, Len(ECHO), PING_TIMEOUT)

Ping = ECHO.status

Call IcmpCloseHandle(hPort)

End If

Else

Ping = INADDR_NONE

End If

Exit Function

ErrLine:

Ping = INADDR_NONE

End Function

Public Function PingIP(ByVal szIp As String) As Boolean

On Error GoTo ErrLine

Dim WSAD As WSADATA

Dim ECHO As ICMP_ECHO_REPLY

Dim ret As Long

'Delay 150

PingIP = False

PingTime = Empty

If WSAStartup(WS_VERSION_REQD, WSAD) = IP_SUCCESS Then

ret = Ping(Trim(szIp), "tanaya", ECHO)

PingTime = ECHO.RoundTripTime

If InStr(1, GetStatusCode(ret), "success") 0 Then

WSACleanup

PingIP = True

PingTime = ECHO.RoundTripTime

Exit Function

End If

End If

Exit Function

ErrLine:

End Function

然后建立一窗體,一command

Private Sub Command1_Click()

If PingIP("你需要訪問的ip") = True Then

'你自己增加需要執(zhí)行的代碼

else

'增加不聯(lián)網(wǎng)時需要執(zhí)行的代碼

end if

VB如何添加inet控件?

VB添加inet控件步驟:

運行VB6.0,新建工程。

菜單工程-部件,在Microsoft Internet Transfer Control 6.0部件前勾選,確定,就可將Inet控件添加到工具箱。

雙擊工具箱Inet控件,窗體上就添加了該控件。

Microsoft Internet Transfer 控件:

Internet Transfer 控件支持超文本傳輸協(xié)議 (HTTP) 和文件傳輸協(xié)議 (FTP),它們是 Internet 網(wǎng)上使用最廣泛的兩種協(xié)議。

使用 HTTP 協(xié)議,可以連接全球信息網(wǎng)(World Wide Web)服務器,以檢索 HTML 文檔。使用 FTP 協(xié)議可以在 FTP服務器上登錄,以下載和加載文件。UserName 和 Password 屬性可讓您在要求驗證身份的私有的服務器上進行登錄。另外,也可以連接公用的 FTP 服務器,并下載文件。Execute 方法支持普通的 FTP

命令,如 CD 和 GET。

關于VB inet控件使用出錯的問題

'郵件已回,請收.

'在這里也隨便說一下,你把你的代碼照下面這樣改正就OK了.

Private Sub downloadone_Click()

Dim strSite As String, strFile As String, strCommand As String

strSite = ""

strFile = "思科路由器常用配置命令大全.txt"

ftpone.Protocol = icFTP

ftpone.URL = strSite '這里改過,調(diào)整了代碼順序,這是必須的

ftpone.UserName = "upload"

ftpone.Password = "upload"

'下面是我改過的代碼

strCommand = "Get " "/upload_1/" strFile " D:\" strFile

ftpone.Execute , strCommand

End Sub

===============================================

星期一給你答復.

===============================================

連接到FTP服務器有兩個重要參數(shù)!

1.FTP的地址,也即是域名,或者IP地址.

2.端口.一般來說FTP使用21號端口,也有例外.

檢查你這兩個參數(shù)對沒有.

你最好ping一個你的FTP地址.

===============================================

我暈啊,你自己好好檢查你的用戶名和密碼吧.還要注意用戶名的大小寫.

哎,你可不可以把你的整個VB工程,打個包發(fā)給我看看啊.我?guī)湍愀母?

xie_jian_jun@163.com,順便要說明你的錯誤現(xiàn)象.

VB里面沒有inet控件

企業(yè)版應該有的,用法 工程-----部件-------勾選Microsoft internet transfer control 6.0---應用----確定,工具箱里就會有inet控件。找不到Microsoft internet transfer control 6.0的話,下載msinet.ocx 放到c:\windows\system32\下,注冊,然后用法同上

VB 中 inet 控件問題

幫你加上注釋吧,暈倒... On Error Resume Next '發(fā)生錯誤時繼續(xù)下一步Inet1.AccessType = 2 '訪問類型

Inet1.RequestTimeout = 60 '請求超時

Inet1.Proxy = "HTTP=" "59.74.42.152" ":" "8080" '代理

Inet1.OpenURL (" ") '打開的網(wǎng)址

MsgBox Val(Mid(Trim(Inet1.GetHeader), 10, 3))

If Err Then

If Err.Number = 35756 Then MsgBox "代理不可用"

MsgBox Err.Number ":" Err.Description

End If

End Sub

本文名稱:vb.netinet的簡單介紹
分享URL:http://chinadenli.net/article10/hegjdo.html

成都網(wǎng)站建設公司_創(chuàng)新互聯(lián),為您提供企業(yè)建站、動態(tài)網(wǎng)站、網(wǎng)站維護虛擬主機、小程序開發(fā)、營銷型網(wǎng)站建設

廣告

聲明:本網(wǎng)站發(fā)布的內(nèi)容(圖片、視頻和文字)以用戶投稿、用戶轉載內(nèi)容為主,如果涉及侵權請盡快告知,我們將會在第一時間刪除。文章觀點不代表本網(wǎng)站立場,如需處理請聯(lián)系客服。電話:028-86922220;郵箱:631063699@qq.com。內(nèi)容未經(jīng)允許不得轉載,或轉載時需注明來源: 創(chuàng)新互聯(lián)

成都seo排名網(wǎng)站優(yōu)化